Natural Ventilation

Natural Turbine Ventilator

Working Procedure

The turbine ventilator operates by utilizing the velocity energy of the win d to induce air flow by centrifugal action. The centrifugal force caused by the spinning vanes creates a region of low pressure area which draws air out through the turbine. Air drawn out by the turbine is continuously replaced by fresh air from the outside. The slightest breeze will cause the turbine to spin and even otter the breeze has stopped, the fly wheel effect of the rotor cage will use its stored energy for continuously remove air giving rise to ventilation. Suction is maintained even at low wind velocities

Recommended Air Change Rates

Type of buildingAir Chang as per hourType of bu ildingAir Changes per hour
Factories (Heavy)10-30Paper Mill8-30
Boiler room10-30Textile Mill4-12
Pocking room8-30Trans former room12 -30
Engine room12-30Pain t shops10-30
Factories (light)6-12Warehouse4-6
Recommended Air Change Rates

Type of building Air Chang as per hour
Factories (Heavy) 10-30
Boiler room 10-30
Pocking room 8-30
Engine room 12-30
Factories (light) 6-12
Paper Mill 8-30
Textile Mill 4-12
Trans former room 12 -30
Pain t shops 10-30
Warehouse 4-6
Performance Data

WIND VELOCITY (MPH)5810
TEMP DIFE     C (Outside & Inside Temp)351035103510

SL.

NO.

THROAT

SIZE (IN)

STACK

HEIGHT (FT.)

EXHAUST CAPACITY IN CFM

 

 

01

 

 

02

 

 

 

03

 

 

20

 

 

22

 

 

 

24

10

20

30

40

10

20

30

40

10

20

30

40

939

1005

1058

1107

1050

1130

1198

1257

1163

1257

1339

1407

1000

1084

1154

1216

1126

1128

1315

1390

1252

1372

1476

1564

1102

1216

1314

1398

1251

1390

1509

1612

1400

1564

1704

1826

1436

1503

1556

1605

1598

1680

1747

1806

1763

1857

1939

2007

1498

1582

1652

1714

1675

1777

1864

1939

1852

1972

2076

2164

1600

1714

1812

1896

1800

1939

2058

2161

2000

2164

2304

2126

1792

1859

1915

1961

1989

2070

2139

2194

2187

2282

2363

2428

1854

1938

2010

2070

2065

2167

2255

2328

2276

2396

2500

2586

1958

2070

2168

2252

2191

2328

2448

2551

2424

2586

2728

2850

Advantages

10 years warranty
Easily replaceabe
Light weight and durable
Virtually maintenance free
Weather proof and storm proof
Available with Aluminum & Stainless Steel Materials
Ro tor shaft and bearing assembly concealed in aluminum or stainless steel casing.
Application

Factories, warehouses, workshops and even community buildings are frequently constructed without an efficient natural ventilation system for the benefit of occupants.
And, if the interior of the building get hot and stale, there’s always door or window that can be opened to provide for the ventilation.
However, stale and hot air doesn’t disperse by itself and opening doors or windows is simply not sufficient to provide adequate ventilation in most buildings. But, by installing AIRVENT Turbine Ventilators, you can provide an efficient and cost effective system of natural ventilation for the benefit of the building’s occupants.
These powerless Ventilators, unlike door or window, draw air upwards, creating a convention current, and in the process it is extracting stale air, together with the air which has become hot due to the building’s exposure to long hours of sunlight and from manufacturing processes within the building. As the stole and hot air is extracted by the ventilators, it is replaced by fresh air at ambient temperature entering
through always and openings thus completing the convention cycle current and improving internal environment.
Needless to say, fresh air make people feel more energetic whilst stole air ca uses people to feel tired and on hot days the air movement over the body causes evaporation to occur which is the natural way of cooling down and reducing heat stress on the body.
Air vent Turbine Ventilator also helps to prevent con-dentations by extracting moist condensate foaming air, and in the case of fire will extract smoke and fumes thus preventing the building from becoming smoke filled and allowing the occupants to escape to safety.
Natural Roof Ventilator

Blade materials: Aluminum or Stainless steel
Adapter materials: Galvanized sheet or Stainless steel
Applications :

Ventilating heat in industry.
Ventilating heat in the house.
Calculation for Exact Quantity

Determine volume of space to be ventilated
Volume (ft3) = L x W x H
Where L = Length, W = Width, H = Height of building
Select Air change Rate
Calculate required ventilation rate Q (cfm)
Q (cfm) =(Volume (ft3) X Air change Rate)/60
Determine number of ventilation= (Ventilation Rate Q)/(Exhaust Capacity)
Size Ø (A) Number of blades Blade DiameterØ (B) Weight (kg) The efficiency of the ventilation(Average speed 6 Miles /Hour)
22” 36” 28” 7.2 170,000 CFH
25” 42” 30” 8.2 190,000 CFH

 

Size Ø (A)           

 

22”

25”

Number of blades

 

36”

42”

Blade DiameterØ (B)

 

28”

30”

Weight (kg)

 

7.2

8.2

The efficiency of the ventilation(Average speed 6 Miles /Hour)

 

170,000 CFH

190,000 CFH

New Valued Added of New 

Natural Ventilation

 Energy Ventilator (NEV)

  • Ability to generate electrical power by natural wind and store in batte The system will give you a various advantages such as LED Lighting, battery charger, mobile phone charger, emergency light and etc.
  • When the absence of wind, the system will return an electrical power from battery back to motorize fan itself.
  • It said that “NEV is a never stop ventilator”

Eco-friendly Product

  • Renewable Energy:
  • Sustainable or Alternative Energy:
  • Emergency Energy:

 Maximum Power (95 w)

Technical Specification

  • Starting Wind…………………………….. 1 m/sec
  •   Cut in Wind………………………………..  2 m/s
  •   Highest Rated Wind……………………  13
  • Average Wind…………………………….  5 m/se
  •   Maximum Power………………………..  95 w
  •   Ventilator diameter…………………….  25 inches